Série 35L, électrovanne à commutation rapide

Fonction: 2/2 et 3/2 NO-NC - Débit: 170Nl - Raccordement: 1/8"
Description du produit
Documentation européenne S35L 

Application MAC,  précautions d'installation et des services

 Fonctionnement

 Documentation américaine
S35L

Mac Valves new

Serie 35L


The MAC 35L Series is a direct solenoid operated 3-way poppet valve featuring our Bullet Valve™ technology . 
The Bullet Valve™ design is a unique hybrid technology that utilizes a "lifting" solenoid (denoted by the "L" in 35L) with an integrated armature/balanced poppet.  The solenoid configuration features fewer parts and fewer wear points than our standard 35 series solenoid.  Our lifting solenoid design is isolated from airline contaminants and our signature balanced design means consistent shifting forces and repeatable response times regardless of inlet pressure.


Fonction Raccordement Débit (Max) Montage

2/2 NO-NC
3/2 NO-NC

1/8"

170Nl En ligne

 
35 series Pic 30

 

                               35 series section 40

 


 

   SERIES FEATURES

• Patented MACSOLENOID® for fastest possible
   response times.

• Bonded balanced poppet for high flow, precise
   repeatability, and consistent operation.

• Balanced poppet permits versatility in function -
   may be used as 3-way or 2-way normally open
   or normally closed and may be used for vacuum,
   divertor, or selector applications.

• Extremely high cycle rate capability

• Use on lube or non-lube service.

• Manual overrides as standard.

• Various solenoid enclosures and plug-in connectors.

• Optional surge suppression (M.O.V. or Diode)
   available.

• Low wattage DC solenoids - down to 1.8 watts.

• Pattended MACSOLENOID® - virtually burn-out proof
   on AC service.

 

   OPERATIONAL BENEFITS

• Balanced poppet, immune
    to variations of pressure.

• Short stroke with high flow.

• Patented solenoid develops
    high shifting forces.

• Powerful return spring.

• Manual operator standard on all
    valves.

• Burn-out proof solenoid on
    AC service.

 