 Type approval certificate 
 | 
 ATEX - II 1 G EEx ia IIC T6 
 | 
| 
 INTRINSIC SAFETY PARAMETERS 
 | 
  | 
| 
 Working temperature 
 | 
 -20°C to +70°C 
 | 
| 
 Input voltage 
 | 
 Vi 30V 
 | 
| 
 Input current 
 | 
 Ii 100mA 
 | 
| 
 Max. input power 
 | 
 Pi 0.75W 
 | 
| 
 Input capacity 
 | 
 Ci ~= 0 
 | 
| 
 Input inductance 
 | 
 Li ~= 0 
 | 
| 
 Electrical connection 
 | 
 DIN 43650 – PG09 
 | 
| 
 Adjusting range 
 | 
 0,15…300 bar 
 | 
| 
 Max static pressure 
 | 
 600 bar 
 | 
| 
 Hysteresis 
 | 
 £ 30% set-point adjustment 
 | 
| 
 Contact (without pressure) 
 | 
 SPDT 
 | 
| 
 Body material 
 | 
 Anodized aluminium 
Flange: nickel-plated steel 
 | 
| 
 Diaphragm/Piston seal 
 | 
 NBR 
 | 
| 
 Threads 
 | 
 Taper: G1/8" – G1/4" 
 | 
| 
 Protection 
 | 
 IP65 
 | 
| 
 Mechanical life 
 | 
 106 operations 
 | 
| 
 Size 
 | 
 Body 30x30 + connector 37x30 
Height 58mm; with connector max. 78mm 
 | 
| 
 Options 
 | 
 Set-point adjustment rising – Set-point adjustment falling – Gold contacts – Degreasing for oxygen applications – Execution with 2 SPDT contacts 
 |